BN series AC frequency conversion power supply from 500VA to 500kVA, a complete variety, widely used in home appliances, motors, laboratories and other places.
Product features:
(1) The product as a whole adopts mature inverter technology, stable and reliable
(2) The output waveform is pure and the waveform distortion is low
(3) Strong overload capacity
(4) The dynamic response speed is fast, and the voltage mutation reaction time is within 20ms
(5) The output voltage and frequency can be adjusted under the starting state, and the use is flexible
(6) With voltage floating up and down quick operation, quickly test the performance of the equipment within the allowed fluctuation range of rated voltage
(7) With 110V/220V, 50Hz/60Hz and other shortcut keys, one key in place, improve daily work efficiency
(8) Voltage can be segmented design: 1.0 ~ 150.0V, 150.1 ~ 300.0V or 0.0 ~ 300.0V, according to customer needs to achieve high grade and low grade full power output
(9) Built-in measuring circuit, can measure voltage, current, active power and other electrical parameters
(10) With intelligent monitoring function, real-time monitoring of internal voltage, current, temperature and other parameters, once abnormal, immediate alarm, prompting the operator to deal with it in time
(11) The main components are purchased from well-known international brands, and the key circuits such as drive and filter have been tested by customers for many years, and the product quality is reliable, stable and durable
(12) The key technical indicators of the whole machine adopt the multi-margin design concept, voltage stress, current stress, calorific value have been strictly technical demonstration, and strict type test, high reliability, long life
Technical parameters:
Product name | Single-phase AC variable frequency power supply | |||||||
Product model | BN31010 | BN31015 | BN31020 | BN31030 | BN31045 | BN31060 | BN31100 | |
Output capacity | 10kVA | 15kVA | 20kVA | 30kVA | 45kVA | 60kVA | 100kVA | |
Basic function | ||||||||
Output function | Simulate power grid voltages around the world | |||||||
Isolation function | Built-in isolating transformer | |||||||
Connection mode | Input: three-phase and four-wire Output: single-phase two-wire | |||||||
Output parameter | ||||||||
Output phase number | Single-phase two-wire+PE | |||||||
Output mode | Single-phase sine wave | |||||||
Output voltage | Automatic: Low:1.0 ~ 150.0V Rated voltage: 110.0V Premium:150.1 ~ 300.0V Rated voltage: 220.0V High-end lock:1.0 ~ 300.0V Rated voltage: 220.0V | |||||||
Voltage setting accuracy | Accuracy:≤0.5% resolution: 0.1V | |||||||
Rated current | low-end | 91.0 A | 136.3 A | 181.8 A | 272.7 A | 409.1 A | 545.4 A | 909.1 A |
Top grade | 45.4 A | 68.1 A | 90.9 A | 136.3 A | 204.5 A | 272.7 A | 454.5 A | |
Output frequency | 45.0-65.0Hz, 100Hz, 120Hz, 200Hz, 240Hz | |||||||
Frequency setting accuracy | Accuracy:≤0.05% Resolution: 0.1Hz | |||||||
Frequency stability | 0.05% or less | |||||||
Voltage distortion (VTHD) | The <1.5%(linear load) | |||||||
Reaction time | ≤2ms | |||||||
Voltage sudden change response time | ≤20ms | |||||||
Crest factor | 1.41 + / - 0.1 | |||||||
Source voltage effect | 1% or less | |||||||
Load effect | 1% or less | |||||||
efficiency | >85% | |||||||
Measurement display | ||||||||
Display mode | HighlightLED display | |||||||
Voltage measurement accuracy | Accuracy:0.2%FS+0.3% Display value resolution: 0.1V | |||||||
Frequency measurement accuracy | Accuracy:0.05% resolution: 0.1 Hz | |||||||
Current measurement accuracy | Accuracy:0.3%FS+0.5% display value resolution: 0.1A/1A | |||||||
Power measurement accuracy | Accuracy:2%FS+3% display value resolution: 0.1kW/0.01kW | |||||||
Feature | ||||||||
Automatic memory function | Set parameter automatic memory, boot automatic call | |||||||
Shortcut group call | 6 groups of quick operation parameter groups for quick switching | |||||||
Shortcut key | 110V/220V, 50Hz/60Hz, the output voltage floating up and down keys | |||||||
Real-time adjustment function | In the startup state, the output voltage and output frequency Settings can be adjusted in real time; | |||||||
Pressure drop compensation function | Impedance compensation:0.001 ~ 0.999 euros | |||||||
Protection function | ||||||||
Overload capacity | 105% < overload ≤110% Cut off the output after 60 seconds 110% < overload ≤120% Cut off the output after 5 seconds | |||||||
Protective device | Output overcurrent, overload protection, output short-circuit protection, overheat protection | |||||||
Remote interface | ||||||||
Communication interface | Standard:RS232 Optional: RS485 | |||||||
Input parameter | ||||||||
Input phase number | Three-phase four-wire+PE | |||||||
Input voltage range | 380V±57V(L-L) | |||||||
Input frequency range | 45 to 65Hz | |||||||
Working environment | ||||||||
Operating temperature | 0 to 40 ° C | |||||||
Working humidity | 20 ~ 90%RH(non-condensation) | |||||||
Volumetric weight | ||||||||
dimension(W×H×Dmm) | 483 * 905 * 650 | 600 * 1000 * 960 | 600 * 1300 * 900 | 750 * 1400 * 1100 | 900 * 1610 * 1310 | |||
weight(Kg) | 197 | 290 | 300 | 320 | 350 | seven hundred | 850 |
Product features:
(1) The product as a whole adopts mature inverter technology, stable and reliable
(2) The output waveform is pure and the waveform distortion is low
(3) Strong overload capacity
(4) The dynamic response speed is fast, and the voltage mutation reaction time is within 20ms
(5) The output voltage and frequency can be adjusted under the starting state, and the use is flexible
(6) With voltage floating up and down quick operation, quickly test the performance of the equipment within the allowed fluctuation range of rated voltage
(7) With 110V/220V, 50Hz/60Hz and other shortcut keys, one key in place, improve daily work efficiency
(8) Voltage can be segmented design: 1.0 ~ 150.0V, 150.1 ~ 300.0V or 0.0 ~ 300.0V, according to customer needs to achieve high grade and low grade full power output
(9) Built-in measuring circuit, can measure voltage, current, active power and other electrical parameters
(10) With intelligent monitoring function, real-time monitoring of internal voltage, current, temperature and other parameters, once abnormal, immediate alarm, prompting the operator to deal with it in time
(11) The main components are purchased from well-known international brands, and the key circuits such as drive and filter have been tested by customers for many years, and the product quality is reliable, stable and durable
(12) The key technical indicators of the whole machine adopt the multi-margin design concept, voltage stress, current stress, calorific value have been strictly technical demonstration, and strict type test, high reliability, long life
Technical parameters:
Product name | Single-phase AC variable frequency power supply | |||||||
Product model | BN31010 | BN31015 | BN31020 | BN31030 | BN31045 | BN31060 | BN31100 | |
Output capacity | 10kVA | 15kVA | 20kVA | 30kVA | 45kVA | 60kVA | 100kVA | |
Basic function | ||||||||
Output function | Simulate power grid voltages around the world | |||||||
Isolation function | Built-in isolating transformer | |||||||
Connection mode | Input: three-phase and four-wire Output: single-phase two-wire | |||||||
Output parameter | ||||||||
Output phase number | Single-phase two-wire+PE | |||||||
Output mode | Single-phase sine wave | |||||||
Output voltage | Automatic: Low:1.0 ~ 150.0V Rated voltage: 110.0V Premium:150.1 ~ 300.0V Rated voltage: 220.0V High-end lock:1.0 ~ 300.0V Rated voltage: 220.0V | |||||||
Voltage setting accuracy | Accuracy:≤0.5% resolution: 0.1V | |||||||
Rated current | low-end | 91.0 A | 136.3 A | 181.8 A | 272.7 A | 409.1 A | 545.4 A | 909.1 A |
Top grade | 45.4 A | 68.1 A | 90.9 A | 136.3 A | 204.5 A | 272.7 A | 454.5 A | |
Output frequency | 45.0-65.0Hz, 100Hz, 120Hz, 200Hz, 240Hz | |||||||
Frequency setting accuracy | Accuracy:≤0.05% Resolution: 0.1Hz | |||||||
Frequency stability | 0.05% or less | |||||||
Voltage distortion (VTHD) | The <1.5%(linear load) | |||||||
Reaction time | ≤2ms | |||||||
Voltage sudden change response time | ≤20ms | |||||||
Crest factor | 1.41 + / - 0.1 | |||||||
Source voltage effect | 1% or less | |||||||
Load effect | 1% or less | |||||||
efficiency | >85% | |||||||
Measurement display | ||||||||
Display mode | HighlightLED display | |||||||
Voltage measurement accuracy | Accuracy:0.2%FS+0.3% Display value resolution: 0.1V | |||||||
Frequency measurement accuracy | Accuracy:0.05% resolution: 0.1 Hz | |||||||
Current measurement accuracy | Accuracy:0.3%FS+0.5% display value resolution: 0.1A/1A | |||||||
Power measurement accuracy | Accuracy:2%FS+3% display value resolution: 0.1kW/0.01kW | |||||||
Feature | ||||||||
Automatic memory function | Set parameter automatic memory, boot automatic call | |||||||
Shortcut group call | 6 groups of quick operation parameter groups for quick switching | |||||||
Shortcut key | 110V/220V, 50Hz/60Hz, the output voltage floating up and down keys | |||||||
Real-time adjustment function | In the startup state, the output voltage and output frequency Settings can be adjusted in real time; | |||||||
Pressure drop compensation function | Impedance compensation:0.001 ~ 0.999 euros | |||||||
Protection function | ||||||||
Overload capacity | 105% < overload ≤110% Cut off the output after 60 seconds 110% < overload ≤120% Cut off the output after 5 seconds | |||||||
Protective device | Output overcurrent, overload protection, output short-circuit protection, overheat protection | |||||||
Remote interface | ||||||||
Communication interface | Standard:RS232 Optional: RS485 | |||||||
Input parameter | ||||||||
Input phase number | Three-phase four-wire+PE | |||||||
Input voltage range | 380V±57V(L-L) | |||||||
Input frequency range | 45 to 65Hz | |||||||
Working environment | ||||||||
Operating temperature | 0 to 40 ° C | |||||||
Working humidity | 20 ~ 90%RH(non-condensation) | |||||||
Volumetric weight | ||||||||
dimension(W×H×Dmm) | 483 * 905 * 650 | 600 * 1000 * 960 | 600 * 1300 * 900 | 750 * 1400 * 1100 | 900 * 1610 * 1310 | |||
weight(Kg) | 197 | 290 | 300 | 320 | 350 | seven hundred | 850 |