BN31 series single-phase AC variable frequency power supply
  • 1652767778953822df963b3c1499b

BN31 series single-phase AC variable frequency power supply

BN series AC frequency conversion power supply from 500VA to 500kVA, a complete variety, widely used in home appliances, motors, laboratories and other places.

Product features:


(1) The product as a whole adopts mature inverter technology, stable and reliable

(2) The output waveform is pure and the waveform distortion is low

(3) Strong overload capacity

(4) The dynamic response speed is fast, and the voltage mutation reaction time is within 20ms

(5) The output voltage and frequency can be adjusted under the starting state, and the use is flexible

(6) With voltage floating up and down quick operation, quickly test the performance of the equipment within the allowed fluctuation range of rated voltage

(7) With 110V/220V, 50Hz/60Hz and other shortcut keys, one key in place, improve daily work efficiency

(8) Voltage can be segmented design: 1.0 ~ 150.0V, 150.1 ~ 300.0V or 0.0 ~ 300.0V, according to customer needs to achieve high grade and low grade full power output

(9) Built-in measuring circuit, can measure voltage, current, active power and other electrical parameters

(10) With intelligent monitoring function, real-time monitoring of internal voltage, current, temperature and other parameters, once abnormal, immediate alarm, prompting the operator to deal with it in time

(11) The main components are purchased from well-known international brands, and the key circuits such as drive and filter have been tested by customers for many years, and the product quality is reliable, stable and durable

(12) The key technical indicators of the whole machine adopt the multi-margin design concept, voltage stress, current stress, calorific value have been strictly technical demonstration, and strict type test, high reliability, long life


Technical parameters:


Product name

Single-phase AC variable frequency power supply

Product model

BN31010

BN31015

BN31020

BN31030

BN31045

BN31060

BN31100

Output capacity

10kVA

15kVA

20kVA

30kVA

45kVA

60kVA

100kVA

Basic function

Output function

Simulate power grid voltages around the world

Isolation function

Built-in isolating transformer

Connection mode

Input: three-phase and four-wire     Output: single-phase two-wire

Output parameter

Output phase number

Single-phase two-wire+PE

Output mode

Single-phase sine wave

Output voltage

Automatic: Low:1.0 ~ 150.0V Rated voltage: 110.0V

         Premium:150.1 ~ 300.0V Rated voltage: 220.0V

High-end lock:1.0 ~ 300.0V Rated voltage: 220.0V

Voltage setting accuracy

Accuracy:≤0.5% resolution: 0.1V

Rated current

low-end

91.0 A

136.3 A

181.8 A

272.7 A

409.1 A

545.4 A

909.1 A

Top grade

45.4 A

68.1 A

90.9 A

136.3 A

204.5 A

272.7 A

454.5 A

Output frequency

45.0-65.0Hz, 100Hz, 120Hz, 200Hz, 240Hz

Frequency setting accuracy

Accuracy:≤0.05% Resolution: 0.1Hz

Frequency stability

0.05% or less

Voltage distortion (VTHD)

The <1.5%(linear load)

Reaction time

≤2ms

Voltage sudden change response time

≤20ms

Crest factor

1.41 + / - 0.1

Source voltage effect

1% or less

Load effect

1% or less

efficiency

>85%

Measurement display

Display mode

HighlightLED display

Voltage measurement accuracy

Accuracy:0.2%FS+0.3% Display value resolution: 0.1V

Frequency measurement accuracy

Accuracy:0.05% resolution: 0.1 Hz

Current measurement accuracy

Accuracy:0.3%FS+0.5% display value resolution: 0.1A/1A

Power measurement accuracy

Accuracy:2%FS+3% display value resolution: 0.1kW/0.01kW

Feature

Automatic memory function

Set parameter automatic memory, boot automatic call

Shortcut group call

6 groups of quick operation parameter groups for quick switching

Shortcut key

110V/220V, 50Hz/60Hz, the output voltage floating up and down keys

Real-time adjustment function

In the startup state, the output voltage and output frequency Settings can be adjusted in real time;

Pressure drop compensation function

Impedance compensation:0.001 ~ 0.999 euros

Protection function

Overload capacity

105% < overload ≤110% Cut off the output after 60 seconds

110% < overload ≤120% Cut off the output after 5 seconds

Protective device

Output overcurrent, overload protection, output short-circuit protection, overheat protection

Remote interface

Communication interface

Standard:RS232 Optional: RS485

Input parameter

Input phase number

Three-phase four-wire+PE

Input voltage range

380V±57V(L-L)

Input frequency range

45 to 65Hz

Working environment

Operating temperature

0 to 40 ° C

Working humidity

20 ~ 90%RH(non-condensation)

Volumetric weight

dimension(W×H×Dmm)

483 * 905 * 650

600 * 1000 * 960

600 * 1300 * 900

750 * 1400 * 1100

900 * 1610 * 1310

weight(Kg)

197

290

300

320

350

seven hundred

850


Product features:


(1) The product as a whole adopts mature inverter technology, stable and reliable

(2) The output waveform is pure and the waveform distortion is low

(3) Strong overload capacity

(4) The dynamic response speed is fast, and the voltage mutation reaction time is within 20ms

(5) The output voltage and frequency can be adjusted under the starting state, and the use is flexible

(6) With voltage floating up and down quick operation, quickly test the performance of the equipment within the allowed fluctuation range of rated voltage

(7) With 110V/220V, 50Hz/60Hz and other shortcut keys, one key in place, improve daily work efficiency

(8) Voltage can be segmented design: 1.0 ~ 150.0V, 150.1 ~ 300.0V or 0.0 ~ 300.0V, according to customer needs to achieve high grade and low grade full power output

(9) Built-in measuring circuit, can measure voltage, current, active power and other electrical parameters

(10) With intelligent monitoring function, real-time monitoring of internal voltage, current, temperature and other parameters, once abnormal, immediate alarm, prompting the operator to deal with it in time

(11) The main components are purchased from well-known international brands, and the key circuits such as drive and filter have been tested by customers for many years, and the product quality is reliable, stable and durable

(12) The key technical indicators of the whole machine adopt the multi-margin design concept, voltage stress, current stress, calorific value have been strictly technical demonstration, and strict type test, high reliability, long life


Technical parameters:


Product name

Single-phase AC variable frequency power supply

Product model

BN31010

BN31015

BN31020

BN31030

BN31045

BN31060

BN31100

Output capacity

10kVA

15kVA

20kVA

30kVA

45kVA

60kVA

100kVA

Basic function

Output function

Simulate power grid voltages around the world

Isolation function

Built-in isolating transformer

Connection mode

Input: three-phase and four-wire     Output: single-phase two-wire

Output parameter

Output phase number

Single-phase two-wire+PE

Output mode

Single-phase sine wave

Output voltage

Automatic: Low:1.0 ~ 150.0V Rated voltage: 110.0V

         Premium:150.1 ~ 300.0V Rated voltage: 220.0V

High-end lock:1.0 ~ 300.0V Rated voltage: 220.0V

Voltage setting accuracy

Accuracy:≤0.5% resolution: 0.1V

Rated current

low-end

91.0 A

136.3 A

181.8 A

272.7 A

409.1 A

545.4 A

909.1 A

Top grade

45.4 A

68.1 A

90.9 A

136.3 A

204.5 A

272.7 A

454.5 A

Output frequency

45.0-65.0Hz, 100Hz, 120Hz, 200Hz, 240Hz

Frequency setting accuracy

Accuracy:≤0.05% Resolution: 0.1Hz

Frequency stability

0.05% or less

Voltage distortion (VTHD)

The <1.5%(linear load)

Reaction time

≤2ms

Voltage sudden change response time

≤20ms

Crest factor

1.41 + / - 0.1

Source voltage effect

1% or less

Load effect

1% or less

efficiency

>85%

Measurement display

Display mode

HighlightLED display

Voltage measurement accuracy

Accuracy:0.2%FS+0.3% Display value resolution: 0.1V

Frequency measurement accuracy

Accuracy:0.05% resolution: 0.1 Hz

Current measurement accuracy

Accuracy:0.3%FS+0.5% display value resolution: 0.1A/1A

Power measurement accuracy

Accuracy:2%FS+3% display value resolution: 0.1kW/0.01kW

Feature

Automatic memory function

Set parameter automatic memory, boot automatic call

Shortcut group call

6 groups of quick operation parameter groups for quick switching

Shortcut key

110V/220V, 50Hz/60Hz, the output voltage floating up and down keys

Real-time adjustment function

In the startup state, the output voltage and output frequency Settings can be adjusted in real time;

Pressure drop compensation function

Impedance compensation:0.001 ~ 0.999 euros

Protection function

Overload capacity

105% < overload ≤110% Cut off the output after 60 seconds

110% < overload ≤120% Cut off the output after 5 seconds

Protective device

Output overcurrent, overload protection, output short-circuit protection, overheat protection

Remote interface

Communication interface

Standard:RS232 Optional: RS485

Input parameter

Input phase number

Three-phase four-wire+PE

Input voltage range

380V±57V(L-L)

Input frequency range

45 to 65Hz

Working environment

Operating temperature

0 to 40 ° C

Working humidity

20 ~ 90%RH(non-condensation)

Volumetric weight

dimension(W×H×Dmm)

483 * 905 * 650

600 * 1000 * 960

600 * 1300 * 900

750 * 1400 * 1100

900 * 1610 * 1310

weight(Kg)

197

290

300

320

350

seven hundred

850