By adopting a current closed-loop control strategy, stable current output is achieved without being affected by load changes. Compared to the traditional testing method of voltage source+load+device under test, this method reduces capacity, energy consumption, and eliminates large capacity loads.
Product Features:
(1)Adopting a current closed-loop control strategy to achieve stable current output, unaffected by load changes. Compared to the traditional testing method of voltage source+load+device under test, this method reduces capacity, energy consumption, and eliminates large capacity loads.
(2) Adopting SPWM high-frequency inverter method to achieve constant current output, compared with motor regulated constant current source, the constant current accuracy is high, the response speed is fast, the distortion is small, and the efficiency is high. The temperature drift caused by external temperature changes can be ignored, which is the future development trend of industry testing
(3) High output current, with a maximum current of several thousand amperes, suitable for distribution cabinet busbars and circuit breaker aging testing
(4) Wide range of output current and frequency settings to meet the needs of different industries
(5) Built in electrical energy measurement circuit, capable of measuring parameters such as current, voltage, frequency, power, testing time, etc
(6) Fast dynamic response speed, with a response time of less than 20ms for sudden load changes
(7) The output current and frequency settings can be adjusted in real-time and the output can be updated immediately
(8) The key technical indicators of the whole machine adopt the concept of multi margin design, and the voltage stress, current stress, and heat generation have undergone strict technical verification and rigorous type testing, resulting in high reliability and long service life.
(1)Single phase AC constant current source
product name | Single phase AC constant current source | ||||||||||
Model | BA5110-30S | BA5120-30S | BA5150-15S | BA51100-115S | BA51200-15S | BA53400-15S | BA53600-15S | BA53800-15S | BA531000-15S | BA532000-15S | BA533000-15S |
Current range | 0~10A | 0~20A | 0~50A | 0~100A | 0~200A | 0~400A | 0~600A | 0~800A | 0~1000A | 0~2000A | 0~3000A |
open circuit voltage | 30V | 15V | |||||||||
basic function | |||||||||||
output function | Output stable current value | ||||||||||
Isolation function | Built in isolation transformer | ||||||||||
Connection | Input terminal: single-phase two-wire Output terminal: single-phase two-wire | Input terminal: three-phase four wire output terminal: single-phase two wire | |||||||||
input parameter | |||||||||||
Input phase number | Single phase two-wire+PE | Three phase four wire+PE | |||||||||
Input Voltage | 220V±22V(L-N) | 380V±38V(L-L) | |||||||||
Input frequency range | 48~52Hz | ||||||||||
Input power factor | 0.93 | ||||||||||
Output parameters | |||||||||||
Output phase number | Single phase two-wire+PE | ||||||||||
Output waveform | Single phase sine wave output | ||||||||||
Accuracy of current setting | accuracy:≤0.5% resolution:0.01A/0.1A | accuracy:≤0.5% resolution:0.1A/1A | |||||||||
Frequency | 45.0~65.0Hz | ||||||||||
Frequency setting accuracy | accuracy:≤0.1% resolution:0.1Hz | ||||||||||
Test time | 0.0~99.9s | ||||||||||
time accuracy | accuracy:≤0.1%+0.1s resolution:0.1s | ||||||||||
Frequency stability | ≤0.1% | ||||||||||
Current distortion degree(ITHD) | <3%(Linear Load) | ||||||||||
Response time for sudden load changes | ≤20ms | ||||||||||
current crest factor | 1.41±0.1 | ||||||||||
source voltage effect | ≤1% | ||||||||||
loading effect | ≤1% | ||||||||||
efficiency | >85% | ||||||||||
functional operation | |||||||||||
waveform mode | sine wave | ||||||||||
Automatic memory function | Set parameters for automatic memory and automatic call upon startup | ||||||||||
Real time adjustment function | In the output state, the output current and frequency settings can be adjusted in real time by pressing the increase and decrease keys, and the output can be updated immediately; | ||||||||||
Quick call | 6 quick groups; | ||||||||||
Measurement display | |||||||||||
display mode | LCD screen | ||||||||||
Accuracy of current measurement | accuracy:0.2%FS+0.3%Display Value resolution:0.01A/0.1A | accuracy:0.2%FS+0.3%Display Value resolution:0.1A/1A | |||||||||
Voltage measurement accuracy | accuracy:0.2%FS+0.3%Display Value resolution:0.001V | ||||||||||
Frequency measurement accuracy | accuracy:0.1% resolution:0.1Hz | ||||||||||
Power measurment accuracy | accuracy:0.2%FS+0.3%Display Value resolution:1W/0.01kW | ||||||||||
Protection function | |||||||||||
Protector | Open circuit protection, overload protection, overheating protection | ||||||||||
Remote interface | |||||||||||
Interface | standard configuration:RS232Optional:RS485 | ||||||||||
work environment | |||||||||||
operation temperature | 0~40℃ | ||||||||||
Working humidity | 20~90%RH(Non condensing) | ||||||||||
volume weight | |||||||||||
size(W×H×Dmm) | 483×178×400 | 483×750×400 | 483×1000×600 | 483×1400×800 | 750×1400×1100 | ||||||
weight(Kg) | 30 | 30 | 40 | 50 | 60 | 90 | 130 | 200 | 240 | 500 | 800 |
(2)Three phase AC constant current source
Product Features:
(1)Adopting a current closed-loop control strategy to achieve stable current output, unaffected by load changes. Compared to the traditional testing method of voltage source+load+device under test, this method reduces capacity, energy consumption, and eliminates large capacity loads.
(2) Adopting SPWM high-frequency inverter method to achieve constant current output, compared with motor regulated constant current source, the constant current accuracy is high, the response speed is fast, the distortion is small, and the efficiency is high. The temperature drift caused by external temperature changes can be ignored, which is the future development trend of industry testing
(3) High output current, with a maximum current of several thousand amperes, suitable for distribution cabinet busbars and circuit breaker aging testing
(4) Wide range of output current and frequency settings to meet the needs of different industries
(5) Built in electrical energy measurement circuit, capable of measuring parameters such as current, voltage, frequency, power, testing time, etc
(6) Fast dynamic response speed, with a response time of less than 20ms for sudden load changes
(7) The output current and frequency settings can be adjusted in real-time and the output can be updated immediately
(8) The key technical indicators of the whole machine adopt the concept of multi margin design, and the voltage stress, current stress, and heat generation have undergone strict technical verification and rigorous type testing, resulting in high reliability and long service life.
(1)Single phase AC constant current source
product name | Single phase AC constant current source | ||||||||||
Model | BA5110-30S | BA5120-30S | BA5150-15S | BA51100-115S | BA51200-15S | BA53400-15S | BA53600-15S | BA53800-15S | BA531000-15S | BA532000-15S | BA533000-15S |
Current range | 0~10A | 0~20A | 0~50A | 0~100A | 0~200A | 0~400A | 0~600A | 0~800A | 0~1000A | 0~2000A | 0~3000A |
open circuit voltage | 30V | 15V | |||||||||
basic function | |||||||||||
output function | Output stable current value | ||||||||||
Isolation function | Built in isolation transformer | ||||||||||
Connection | Input terminal: single-phase two-wire Output terminal: single-phase two-wire | Input terminal: three-phase four wire output terminal: single-phase two wire | |||||||||
input parameter | |||||||||||
Input phase number | Single phase two-wire+PE | Three phase four wire+PE | |||||||||
Input Voltage | 220V±22V(L-N) | 380V±38V(L-L) | |||||||||
Input frequency range | 48~52Hz | ||||||||||
Input power factor | 0.93 | ||||||||||
Output parameters | |||||||||||
Output phase number | Single phase two-wire+PE | ||||||||||
Output waveform | Single phase sine wave output | ||||||||||
Accuracy of current setting | accuracy:≤0.5% resolution:0.01A/0.1A | accuracy:≤0.5% resolution:0.1A/1A | |||||||||
Frequency | 45.0~65.0Hz | ||||||||||
Frequency setting accuracy | accuracy:≤0.1% resolution:0.1Hz | ||||||||||
Test time | 0.0~99.9s | ||||||||||
time accuracy | accuracy:≤0.1%+0.1s resolution:0.1s | ||||||||||
Frequency stability | ≤0.1% | ||||||||||
Current distortion degree(ITHD) | <3%(Linear Load) | ||||||||||
Response time for sudden load changes | ≤20ms | ||||||||||
current crest factor | 1.41±0.1 | ||||||||||
source voltage effect | ≤1% | ||||||||||
loading effect | ≤1% | ||||||||||
efficiency | >85% | ||||||||||
functional operation | |||||||||||
waveform mode | sine wave | ||||||||||
Automatic memory function | Set parameters for automatic memory and automatic call upon startup | ||||||||||
Real time adjustment function | In the output state, the output current and frequency settings can be adjusted in real time by pressing the increase and decrease keys, and the output can be updated immediately; | ||||||||||
Quick call | 6 quick groups; | ||||||||||
Measurement display | |||||||||||
display mode | LCD screen | ||||||||||
Accuracy of current measurement | accuracy:0.2%FS+0.3%Display Value resolution:0.01A/0.1A | accuracy:0.2%FS+0.3%Display Value resolution:0.1A/1A | |||||||||
Voltage measurement accuracy | accuracy:0.2%FS+0.3%Display Value resolution:0.001V | ||||||||||
Frequency measurement accuracy | accuracy:0.1% resolution:0.1Hz | ||||||||||
Power measurment accuracy | accuracy:0.2%FS+0.3%Display Value resolution:1W/0.01kW | ||||||||||
Protection function | |||||||||||
Protector | Open circuit protection, overload protection, overheating protection | ||||||||||
Remote interface | |||||||||||
Interface | standard configuration:RS232Optional:RS485 | ||||||||||
work environment | |||||||||||
operation temperature | 0~40℃ | ||||||||||
Working humidity | 20~90%RH(Non condensing) | ||||||||||
volume weight | |||||||||||
size(W×H×Dmm) | 483×178×400 | 483×750×400 | 483×1000×600 | 483×1400×800 | 750×1400×1100 | ||||||
weight(Kg) | 30 | 30 | 40 | 50 | 60 | 90 | 130 | 200 | 240 | 500 | 800 |
(2)Three phase AC constant current source