BAVF-3X series single three-phase AC variable frequency power supply
  • 165485130621807b6fe09ee767b29

BAVF-3X series single three-phase AC variable frequency power supply

BAVF series can simulate the power grid voltage of all countries in the world, providing customers with high purity and high reliability sine wave power output, voltage 0-300V, 0.1V adjustable, frequency 45-240Hz, 0.01Hz adjustable, power 15kVA-1000kVA, which can meet the needs of different industries. Widely used in home appliances, motors, certification bodies, medical equipment, lighting and other fields.

Product features:

(1) With a variety of output modes, powerful:

uThree-phase standard mode: Standard three-phase voltage output

uThree-phase unbalanced mode: three-phase voltage is set independently, and three-phase phase Angle is adjustable from 0.0° to 359.9°

uDiscrete single-phase mode: three-phase voltage, frequency independent setting, equivalent to three single-phase power supplies

uParallel single-phase mode: three phases are combined to form high-power single-phase output

(2) The product adopts three-phase decoupling control, which can adapt to 0 ~ 100% load imbalance.

(3) The use of accurate anti-impact technology, can withstand the load of large current impact, 3 times the rated current can mature 2s, especially suitable for motor, motor and other impact equipment.

(4) 8-inch color touch screen, all operations can be achieved through the touch screen, exquisite appearance, convenient operation, and equipped with digital keys, function keys, knobs, etc., diversified operation.

(5) With Auto-Lock function, timed to automatically lock the keyboard to prevent miscontact.

(6) Voltage range design: 0.0 ~ 150.0V, 150.1 ~ 300.0V or 0.0 ~ 300.0V, high grade and low grade can be full power output; Frequency output range 45.00 ~ 65.00Hz, resolution 0.01Hz.

(7) The measurement function is complete, can measure voltage, current, current peak, frequency, active power, apparent power, power factor, voltage peak factor and other power parameters.

(8) With the "black box" function, real-time monitoring of internal voltage, current, temperature and other parameters, abnormal conditions immediately alarm and automatically record operating parameters, convenient for later viewing and maintenance.

(9) Communication interface standard RS232, optional RS485, GPIB, ETHERNET, analog control, etc.

Typical recommendation:

uMultiple output modes, "one machine multi-purpose"

BAST series adopts three-phase decoupling control, combined with digital control algorithm, to achieve a variety of mode output: three-phase standard mode, three-phase unbalanced mode, discrete single-phase mode, parallel single-phase mode, one power supply is equivalent to a variety of traditional power supply functions, so that "one machine with multiple uses".

u Overload capability, start motor, compressor and other equipment more easily

The BAVF series adopts precise current control technology, which can withstand the impact of 3 times the rated current for 2 seconds, and easily cope with 5-10 times the impact current at the start of the load such as motors and compressors.

u8 inch color touch screen, operation experience upgrade.

BAVF series 8 "color touch screen, all operations can be done by touch screen, intuitive, friendly and efficient.

u"Black box" function, real-time monitoring, improve maintenance efficiency.

The BAVF series built-in "black box" function enables real-time monitoring of power operation data and timely recording of input and output parameters in case of abnormal operation, making maintenance easier.


Technical parameters:

Product name

Single three-phase AC variable frequency power supply

Product model

BAVF015-3X

BAVF030-3X

BAVF045-3X

BAVF060-3X

BAVF090-3X

BAVF120-3X

BAVF150-3X

BAVF180-3X

BAVF240-3X

Output capacity

15kVA

30kVA

45kVA

60kVA

90kVA

120kVA

150kVA

180kVA

240kVA

Basic function

Output function

Simulate power grid voltages around the world

Isolation function

Built-in isolating transformer

Output parameter

Output phase number

Three-phase four-wire+PE

Output mode

Standard sine wave mode

exportation

voltage

Automatic transmission

Low:0.0 ~ 150.0V(L-N) High grade: 150.1V ~ 300.0V(L-N)

High level lock

0.0 ~ 300.0V(L-N)

Voltage setting accuracy

Accuracy:≤0.5% resolution: 0.1V

Three-phase standard mode, three-phase unbalanced mode, discrete single-phase mode

rated

Electric current

low-end

45.4 A

90.9 A

136.3 A

181.8 A

272.6 A

363.6 A

454.5 A

545.4 A

727.2 A

Top grade

22.7 A

45.4 A

68.1 A

90.9 A

136.3 A

181.8 A

227.2 A

272.7 A

363.6 A

Shunt single-phase mode

rated

Electric current

low-end

136.3 A

272.7 A

409.1 A

545.5 A

818.2 A

1090.9 A

1363.6 A

1636.3 A

2181.9 A

Top grade

68.2 A

136.3 A

204.5 A

272.7 A

409.1 A

545.4 A

681.8 A

818.2 A

1090.9 A

Output frequency

45.00 to 240.00Hz

Frequency setting accuracy

Accuracy:≤0.02% Resolution: 0.01Hz

Frequency stability

0.02% or less

Voltage distortion (VTHD)

The <1%(linear load)

Reaction time

≤2ms

Voltage sudden change response time

≤20ms

Three-phase phase Angle

2 ° to 120 ° +

Crest factor

1.41 + / - 0.1

Source voltage effect

1% or less

Load effect

1% or less

efficiency

>85%

Measurement display

Display mode

8 inch color touch screen

Voltage measurement accuracy

Accuracy:0.2%FS+0.2% display value resolution: 0.1V

Frequency measurement accuracy

Accuracy:0.02% Resolution: 0.01Hz

Current measurement accuracy

Accuracy:0.3%FS+0.3% Display value resolution: 0.1A/1A

Power measurement accuracy

Accuracy:0.5%FS+0.5% display value resolution: 0.1kW/0.01kW/0.001kW

Functional operation

Automatic memory function

Set parameter automatic memory, boot automatic call

Soft boot

With soft start function, soft start timeThe value ranges from 0.0 to 99.9s

Real-time adjustment function

In the startup state, the output voltage and frequency Settings can be adjusted through the touch screen, digital key, increase or decrease key, knob, and immediately updated;

Pressure drop compensation function

Impedance compensation:0.000 ~ 0.500 euros

Shortcut call

Conventional mode10 shortcut groups

Protection function

Overload capacity

105% < overload ≤110% Cut off the output after 15 seconds 110% < overload ≤200% Cut off the output after 5 seconds 200% < overload ≤300% Cut off the output after 2 seconds 300% < Overload immediately cut off the output

Protective device

Over current, overload, short circuit protection, overheat protection, output over and under voltage, phase protection

Software protection

Artificial intelligence monitoring(AI-Monitor) function, Black-Box function, Auto-Lock key lock protection

Remote interface

Communication interface

Standard:RS232 Optional: RS485, GPIB, ETHERNET

Remote control

Analog control port(optional)

Input parameter

Input phase number

Three-phase four-wire+PE

Input voltage range

380V±57V(L-L)

Input frequency range

45 to 65Hz

Working environment

Operating temperature

0 to 40 ° C

Working humidity

20 ~ 90%RH(non-condensation)

Volumetric weight

dimension(W×H×Dmm)

600 * 1150 * 1020

700 * 1350 * 1220

800 * 1750 * 1420

Weight (Kg)

265

310

440

550

740

980
125012701400

Dear, your site service has expired, please contact us to renew oh!


Product features:

(1) With a variety of output modes, powerful:

uThree-phase standard mode: Standard three-phase voltage output

uThree-phase unbalanced mode: three-phase voltage is set independently, and three-phase phase Angle is adjustable from 0.0° to 359.9°

uDiscrete single-phase mode: three-phase voltage, frequency independent setting, equivalent to three single-phase power supplies

uParallel single-phase mode: three phases are combined to form high-power single-phase output

(2) The product adopts three-phase decoupling control, which can adapt to 0 ~ 100% load imbalance.

(3) The use of accurate anti-impact technology, can withstand the load of large current impact, 3 times the rated current can mature 2s, especially suitable for motor, motor and other impact equipment.

(4) 8-inch color touch screen, all operations can be achieved through the touch screen, exquisite appearance, convenient operation, and equipped with digital keys, function keys, knobs, etc., diversified operation.

(5) With Auto-Lock function, timed to automatically lock the keyboard to prevent miscontact.

(6) Voltage range design: 0.0 ~ 150.0V, 150.1 ~ 300.0V or 0.0 ~ 300.0V, high grade and low grade can be full power output; Frequency output range 45.00 ~ 65.00Hz, resolution 0.01Hz.

(7) The measurement function is complete, can measure voltage, current, current peak, frequency, active power, apparent power, power factor, voltage peak factor and other power parameters.

(8) With the "black box" function, real-time monitoring of internal voltage, current, temperature and other parameters, abnormal conditions immediately alarm and automatically record operating parameters, convenient for later viewing and maintenance.

(9) Communication interface standard RS232, optional RS485, GPIB, ETHERNET, analog control, etc.

Typical recommendation:

uMultiple output modes, "one machine multi-purpose"

BAST series adopts three-phase decoupling control, combined with digital control algorithm, to achieve a variety of mode output: three-phase standard mode, three-phase unbalanced mode, discrete single-phase mode, parallel single-phase mode, one power supply is equivalent to a variety of traditional power supply functions, so that "one machine with multiple uses".

u Overload capability, start motor, compressor and other equipment more easily

The BAVF series adopts precise current control technology, which can withstand the impact of 3 times the rated current for 2 seconds, and easily cope with 5-10 times the impact current at the start of the load such as motors and compressors.

u8 inch color touch screen, operation experience upgrade.

BAVF series 8 "color touch screen, all operations can be done by touch screen, intuitive, friendly and efficient.

u"Black box" function, real-time monitoring, improve maintenance efficiency.

The BAVF series built-in "black box" function enables real-time monitoring of power operation data and timely recording of input and output parameters in case of abnormal operation, making maintenance easier.


Technical parameters:

Product name

Single three-phase AC variable frequency power supply

Product model

BAVF015-3X

BAVF030-3X

BAVF045-3X

BAVF060-3X

BAVF090-3X

BAVF120-3X

BAVF150-3X

BAVF180-3X

BAVF240-3X

Output capacity

15kVA

30kVA

45kVA

60kVA

90kVA

120kVA

150kVA

180kVA

240kVA

Basic function

Output function

Simulate power grid voltages around the world

Isolation function

Built-in isolating transformer

Output parameter

Output phase number

Three-phase four-wire+PE

Output mode

Standard sine wave mode

exportation

voltage

Automatic transmission

Low:0.0 ~ 150.0V(L-N) High grade: 150.1V ~ 300.0V(L-N)

High level lock

0.0 ~ 300.0V(L-N)

Voltage setting accuracy

Accuracy:≤0.5% resolution: 0.1V

Three-phase standard mode, three-phase unbalanced mode, discrete single-phase mode

rated

Electric current

low-end

45.4 A

90.9 A

136.3 A

181.8 A

272.6 A

363.6 A

454.5 A

545.4 A

727.2 A

Top grade

22.7 A

45.4 A

68.1 A

90.9 A

136.3 A

181.8 A

227.2 A

272.7 A

363.6 A

Shunt single-phase mode

rated

Electric current

low-end

136.3 A

272.7 A

409.1 A

545.5 A

818.2 A

1090.9 A

1363.6 A

1636.3 A

2181.9 A

Top grade

68.2 A

136.3 A

204.5 A

272.7 A

409.1 A

545.4 A

681.8 A

818.2 A

1090.9 A

Output frequency

45.00 to 240.00Hz

Frequency setting accuracy

Accuracy:≤0.02% Resolution: 0.01Hz

Frequency stability

0.02% or less

Voltage distortion (VTHD)

The <1%(linear load)

Reaction time

≤2ms

Voltage sudden change response time

≤20ms

Three-phase phase Angle

2 ° to 120 ° +

Crest factor

1.41 + / - 0.1

Source voltage effect

1% or less

Load effect

1% or less

efficiency

>85%

Measurement display

Display mode

8 inch color touch screen

Voltage measurement accuracy

Accuracy:0.2%FS+0.2% display value resolution: 0.1V

Frequency measurement accuracy

Accuracy:0.02% Resolution: 0.01Hz

Current measurement accuracy

Accuracy:0.3%FS+0.3% Display value resolution: 0.1A/1A

Power measurement accuracy

Accuracy:0.5%FS+0.5% display value resolution: 0.1kW/0.01kW/0.001kW

Functional operation

Automatic memory function

Set parameter automatic memory, boot automatic call

Soft boot

With soft start function, soft start timeThe value ranges from 0.0 to 99.9s

Real-time adjustment function

In the startup state, the output voltage and frequency Settings can be adjusted through the touch screen, digital key, increase or decrease key, knob, and immediately updated;

Pressure drop compensation function

Impedance compensation:0.000 ~ 0.500 euros

Shortcut call

Conventional mode10 shortcut groups

Protection function

Overload capacity

105% < overload ≤110% Cut off the output after 15 seconds 110% < overload ≤200% Cut off the output after 5 seconds 200% < overload ≤300% Cut off the output after 2 seconds 300% < Overload immediately cut off the output

Protective device

Over current, overload, short circuit protection, overheat protection, output over and under voltage, phase protection

Software protection

Artificial intelligence monitoring(AI-Monitor) function, Black-Box function, Auto-Lock key lock protection

Remote interface

Communication interface

Standard:RS232 Optional: RS485, GPIB, ETHERNET

Remote control

Analog control port(optional)

Input parameter

Input phase number

Three-phase four-wire+PE

Input voltage range

380V±57V(L-L)

Input frequency range

45 to 65Hz

Working environment

Operating temperature

0 to 40 ° C

Working humidity

20 ~ 90%RH(non-condensation)

Volumetric weight

dimension(W×H×Dmm)

600 * 1150 * 1020

700 * 1350 * 1220

800 * 1750 * 1420

Weight (Kg)

265

310

440

550

740

980
125012701400

Dear, your site service has expired, please contact us to renew oh!